Description
Power:
6
kW max.Cooling:
Liquid
Isolation:
Isolated
Voltage range low:
18V-36V
Voltage range high:
200V-900V
Features
- Voltage source
- Buck operations
- Liquid cooled
- 3 kV DC isolation between HV and LV
- HVIL on input voltage
- Insulated CAN 2.0B connectivity for control
Applications
- Battery sytems
- Electric vehicles
Product details
Communication and monitoring
Typology | Max | Units | |
---|---|---|---|
CAN 2.0B bus speed (CAN FD) | 1000 | Kb/s | |
CAN periodicity | 20 | ms | |
Measured voltages accuracy | ±0.7 | ±2 | % of full scale |
Measured Low Side current accuracy | ±1.9 | ±3 | % of full scale |
Measured internal temperature accuracy | ±1 | ±3 | °C |
Service Power Supply - Voltage | 32 | V | |
Service Power Supply - Power consumption |
Cooling parameters
Min | Typology | Max | Units | |
---|---|---|---|---|
Flow rate | 3 | 5 | 7 | L/mn |
Pressure | 5 | Bar | ||
Inlet liquid temperature | 0 | +65 | °C |
Regulation Modes
Environment data
Min | Typology | Max | Units | |
---|---|---|---|---|
Ambiant temperature (operating) | -40 | 85 | °C | |
Ingress Protection | IP69K | - |
Standards used for design
EMC | R10 |
Control circuit supply voltage | ISO 16750-2 mode D |
Mechanical loads | ISO 16750-3 |
Climatic loads | ISO 16750-4 code G |
Chemical loads | ISO 16750-5 mounting location A |
Electric vehicle safety | R100 |
Connectors
Connectors | Supplier | Single unit |
---|---|---|
Input Voltage | Amphenol | Amphenol PL082X-121 |
Output Voltage positive | VTE Inc | CCB376M0NR02W (Red) |
Output Voltage negative (casing) | VTE Inc | CCB376M0N14W (Black) |
CAN + Service voltage + HVIL | Amphenol | AT04-12PA-PM11 |
Cooling connectors | Legris | 0931 10 13 |
Casing | - | Threaded stud M8x17 |