Description
Power:
32
kW max.Cooling:
Air
Isolation:
Not isolated
Voltage range low:
300 - 400 V
Voltage range high:
600 - 700 V
Features
- Programmable smart DC/DC converter allowing regulation according to voltage, current or power, input or output
- Buck/boost transition controlled by CAN command
- Operations controlled through insulated CAN 2.0B
- Parallelization of DC/DC modules for higher power delivery (in current source mode only)
- Air cooling
Applications
- Fuel cell power
- Battery systems
- Super capacitors
- Chargers
- Loads
- Motors
Product details
Communication and monitoring
Min | Typology | Max | Units | |
---|---|---|---|---|
CAN 2.0B bus speed | 125 | 500 | Kb/s | |
CAN periodicity | 100 | ms | ||
Measured voltages accuracy | ± 0.7 | ± 2 | % of full scale | |
Measured Low Side current accuracy | ± 1.9 | ± 3 | % of full scale | |
Measured High Side current accuracy | ± 1.7 | ± 2.5 | % of full scale | |
Measured internal temperature accuracy | ± 1 | ± 3 | °C | |
Service Power Supply - Voltage (12V option) | 9 | 12 | 13.5 | V |
Service Power Supply - Voltage (24V option) | 18 | 24 | 18 | V |
Service Power Supply - Power consumption (fans included) | 1 | 30 | W |
Cooling parameters
Min | Typology | Max | Units | |
---|---|---|---|---|
Air flow rate (permanent) | 268 | m³/h | ||
Inlet air temperature | 55 | °C |
Regulation Modes
Current | Voltage | Power | |
---|---|---|---|
According to low side | ✔ | ✔ | ✔ |
According to high side | ✔ | ✔ | ✔ |
Environment data
Min | Typology | Max | Units | |
---|---|---|---|---|
Galvanic insulation between power circuit and chassis-control interface (1 min test) | 3.0 | kV | ||
Insulation resistance | 2 | MΩ | ||
Ambiant temperature (operating) | -40 | 55 | °C | |
Ingress protection | IP20 | - |
Standards used for design
EMC | R10 |
---|---|
Control circuit supply voltage | ISO 16750-2 mode D |
Mechanical loads | ISO 16750-3 |
Climatic loads | ISO 16750-4 code G |
Connectors
V Low side | Copper Bus bar 5 x 16 mm section |
V High side | Copper Bus bar 5 x 16 mm section |
CAN + Service voltage | Female DB15 |